A capacitor bank is usually designed as a thermal system, not a parts list. The original vendor sized the cans, the spacing, the airflow and the ripple margin around one specific ESR and one specific case-to-ambient thermal resistance. When that part goes end-of-life, the replacement that looks electrically equivalent on a parameter table can push the bank 10–15 K hotter and quietly cut its service life by more than half. This article sets out which parameters must be held tight during cross-referencing, which can move, and how to verify the result on the bench.
Why an obsolete can becomes a thermal problem
Ripple heating in a bank is I²R, and R here is the ESR at the actual ripple frequency, not the 100 Hz or 120 Hz value printed in the headline of the datasheet. Two capacitors with identical capacitance and voltage rating can differ by a factor of two in high-frequency ESR, and the resulting hot-spot difference scales directly with that ratio.
The second half of the problem is heat removal. A shorter can with the same diameter has less surface area, and a snap-in with a different terminal geometry may sit differently against the PCB or busbar. Thermal resistance from case to ambient is rarely quoted with enough detail, so it has to be inferred from can dimensions and mounting, then confirmed by measurement.
Treat any substitution that changes can length, terminal style or ESR by more than roughly 20% as a thermal redesign, not a drop-in replacement.
Match strictly versus allow to drift
The table below separates the parameters that define the bank’s thermal behaviour from those that only affect convenience or cost.
| Parameter | Match requirement | Why it matters | Acceptable deviation |
|---|---|---|---|
| Bank total capacitance | Hold within the original tolerance band (typically ±20%) | Loop resonance, pre-charge time, inrush | Up to +20% only if pre-charge and inrush are re-checked |
| Voltage rating | Equal or higher, at the same or higher category temperature | Surge margin and derating headroom | Higher is acceptable |
| Ripple current rating at 100/120 Hz | Equal or higher after frequency correction | Sets the hot spot | Higher is acceptable |
| ESR (max, at ripple frequency, 20 °C) | Within about −20% / +10% of original | Heat generation and current sharing in parallel strings | Lower ESR draws more ripple in a parallel array; re-check sharing |
| Can diameter and length | Equal or larger heat-dissipating surface | Case-to-ambient thermal resistance | A shorter can of the same diameter raises thermal resistance |
| Category temperature (85/105/125 °C) | Equal or higher | Ceiling for the computed hot spot | Higher is acceptable |
| Endurance at rated temperature | Equal or better at the actual hot spot, not at nameplate | Service life | Longer is acceptable |
| Terminal spacing, mounting, vent clearance | Exact | Creepage, mechanical stress, pressure relief | None |
Worked cross-reference: 12-can DC-link bank
Consider a bank of twelve 470 µF / 450 V snap-ins arranged 3 parallel × 4 series, running at 60 °C ambient with 20 kHz ripple. The candidate differs in can length and ESR. The worksheet below shows the numbers that actually decide the substitution.
| Item | Original | Candidate | Acceptance rule |
|---|---|---|---|
| Ripple rating, 100 Hz, 105 °C | 2.10 A | 2.35 A | Candidate ≥ original |
| Frequency correction at 20 kHz | 1.40 | 1.40 | Use vendor coefficients, not assumptions |
| Effective ripple rating at 20 kHz | 2.94 A | 3.29 A | Must exceed actual string ripple with margin |
| ESR max at ripple frequency | 0.28 Ω | 0.24 Ω | Within −20% / +10% |
| Ripple power per can (I = 3.0 A rms) | 2.52 W | 2.16 W | Recompute from measured ESR |
| Can size | 35 × 50 mm | 35 × 45 mm | Surface area must not fall materially |
| Total thermal resistance, core to ambient | 7.0 K/W | 7.7 K/W | Estimate, then confirm by test |
| Computed hot spot at 60 °C ambient | 77.6 °C | 76.6 °C | ≤ category temperature − 10 K |
| Computed life (5000 h at 105 °C base, 10 K doubling) | ≈ 33,000 h | ≈ 36,000 h | Meet the design target with margin |
In this case the shorter can is offset by the lower ESR, and the hot spot improves slightly. Reverse either number — a longer can with the same ESR, or a shorter can with the same ESR — and the calculation turns negative. That is the check that a capacitance-and-voltage comparison alone will never catch.
Verification steps before the bank is released
- Confirm ESR on the actual lot. Measure a sample at the ripple frequency with a four-wire meter; lot-to-lot spread on electrolytics can exceed the datasheet maximum tolerance band.
- Recompute the hot spot with vendor frequency coefficients. Do not scale the 100 Hz rating linearly. Above roughly 10 kHz the correction factor flattens, and a part with a good 100 Hz rating may not hold up.
- Run a thermal soak. Operate the bank at rated ripple and worst-case ambient until can temperatures stabilise, typically two to three hours. Measure the can side wall at the core axis, not the terminal.
- Compare against the original baseline. A rise within 3–5 K of the original is normally acceptable; a larger rise means the thermal resistance or ESR assumption was wrong.
- Check parallel current sharing. Clamp each parallel string with a current probe; unequal ESR splits ripple unevenly and overheats the lowest-ESR branch first.
- Re-verify pre-charge and inrush. Higher bank capacitance lengthens pre-charge and raises inrush energy through the rectifier and contactor.
- Confirm mechanical and venting clearances. Pressure-relief orientation and spacing between cans affect both convection and safety.
Document the measured hot spot, the ambient it was measured at, and the resulting life estimate in the cross-reference record. When the next obsolescence notice arrives, that record is the baseline the following substitution has to beat.