Technical article

Sizing Aluminum Electrolytic Capacitors for Sealed Outdoor LED Drivers: Core Temperature, Ripple Heat and Life Targets

2 views

A 150 W streetlight driver in a die-cast housing has no fan and no vent. On a 40 °C night the air inside the enclosure sits at 65–70 °C, and the PFC bus capacitor runs another 8–12 K above that. The datasheet line “105 °C, 5000 h” describes a test bench, not this board. What governs service life is the core temperature under real ripple current, and that number is set by capacitance choice, ESR and layout long before the part is ordered.

Where the stress comes from in a sealed driver

The PFC stage is the dominant load. A 400 V bus fed from 230 V mains carries a 100 Hz ripple component (120 Hz on 60 Hz grids) whose amplitude scales with output power and inversely with bus capacitance. With a 68 µF bulk capacitor at 100 W output, expect roughly 0.5–0.7 A rms at 100 Hz. Doubling to 150 µF halves the ripple current but costs board area and height — a trade that has to be settled against the thermal budget, not against the BOM alone.

The second capacitor sits on the 48–60 V output rail and sees switching ripple at 60–120 kHz. There, ESR rather than capacitance sets the heating, and the allowable ripple must be read from the frequency correction table rather than the 100 Hz headline figure. Low-impedance series typically allow 1.4–1.8× the 100 Hz rating at 100 kHz; the exact multiplier belongs in the calculation.

Voltage stress is not flat either. A bus designed at 400 V nominal can reach 430–450 V at high line combined with a clamped surge, and 277 V or 347 V mains push the nominal bus higher still. Meanwhile the enclosure adds 15–25 K over outdoor air at 88–92 % driver efficiency, so a capacitor rated 105 °C may be running a 90 °C core on a mild day.

From field stress to a purchase specification

Two equations do most of the work. Self-heating is ΔT = I² × ESR × Rth, and life follows the 10 K rule, L = L0 × 2(T0 − Tx)/10. A 105 °C / 5000 h part with a 75 °C core gives 5000 × 2³ = 40,000 h; at 65 °C it gives 80,000 h. Because the doubling rule over-predicts at low temperature, cap the calculated result at roughly 8–10× the rated load life before quoting it to a customer.

  • Voltage: keep steady-state bus voltage at or below 80 % of the rated value; use 450 V for 120/230 V mains and 500 V where nominal mains exceed 260 V.
  • Ripple: size so that calculated ripple is ≤70 % of the rated value after applying both frequency and temperature multipliers (about 1.4× at 85 °C case, 1.7–1.8× at 70 °C for common series).
  • Self-heating: hold ΔT at the can centre to 3–5 K; above that, ESR drift accelerates and the life calculation loses validity.
  • Life target: a 5-year warranty at 12 h/day is about 22,000 operating hours; specify a computed life of at least 50,000 h at the expected core temperature to leave margin for field temperature excursions.
Parameter Stress in a 150 W sealed driver Minimum purchase spec Verification
Rated voltage 400 V bus, 450 V at high line plus surge clamp 450 V (500 V for 277/347 V mains) Steady-state ≤80 % of rating at nominal line
Ripple current, 100 Hz 0.5–0.7 A rms at full load ≥1.0 A rms at 105 °C, 100 Hz Calculated ripple ≤70 % of rating after multipliers
ESR 3–5 K self-heating budget Low-impedance series, ESR stated at 100 Hz and 100 kHz ΔT = I²·ESR·Rth checked on first article
Load life ~22,000 h over a 5-year warranty 105 °C, 5000 h minimum Computed life ≥50,000 h at 75 °C core
tan δ Bus heating at 100 Hz ≤0.10–0.15 at 120 Hz, 20 °C Incoming sample test
Leakage current First power-up after storage ≤0.01·C·V or datasheet limit Measured after 2 min at rated voltage, 20 °C
Case size ≤20 mm height, 10 mm lead spacing 12.5 × 20 to 16 × 25 mm Fit check with ≥3 mm vent clearance

When an approved part goes obsolete, match on these rows rather than on capacitance alone. A replacement with the same µF and voltage but a higher ESR will run hotter and can halve the calculated life even though it passes a capacitance meter.

Installation, incoming test and field checks

Thermal placement matters more than most designers expect. Keep the can at least 5 mm from the PFC MOSFET heatsink and the transformer, mount it off the hottest region of the PCB, and avoid running it against the housing wall where heat has nowhere to go. Bend leads no closer than 2 mm from the seal, and do not let potting compound cover the pressure relief vent — trapped solvent and gas have to escape somewhere.

A capacitor that reads nominal at 25 °C can be at end of life at 85 °C. Measure ESR and case temperature, not just capacitance.

Incoming inspection should sample capacitance at 120 Hz and 20 °C against the ±20 % tolerance, tan δ, ESR at 100 kHz, and leakage current after two minutes at rated voltage. Parts stored longer than about two years need reforming: bring them up slowly through a series resistor before they go on a production board.

In the field, log can temperature with a thermocouple under full load and treat a 20 % capacitance drop or a doubling of ESR as the replacement trigger. Those two readings track the life equation far more closely than a visual check for bulging, which appears late in the ageing curve.

akkn